Ensure the wires to be terminated are cut flush and cleanly. Important no ragged edges are present on the insulation.
![](https://pcsl.eu/wp-content/uploads/2024/08/gel-crimp-install-1.png)
Fully insert wires fully into the connector base. The wires are visible in the base so you can see they inserted fully past the IDC blade contact. Pre-crimp if required using fingers if performing multiple crimping
![](https://pcsl.eu/wp-content/uploads/2024/08/gel-crimp-install-2.png)
Use a tool for 2/3 wire connector terminations when installing. Apply pressure evenly to the top of the connector during crimping.
![](https://pcsl.eu/wp-content/uploads/2024/08/gel-crimp-install-3.png)
Fully crimp top cover so its flush with base housing top.
![](https://pcsl.eu/wp-content/uploads/2024/08/gel-crimp-install-4.png)
Full range of Gel Crimps , Tools & Connection boxes are available in our store: https://pcsl.eu/product-category/telecom/connection-boxes-and-gel-crimps/